| Environmental
Specifications: |
| Ambient temperature
[°C] |
0-55 |
| Operating temperature
[°C] |
0-55 |
| Storage temperature
[°C] |
-20...+70 |
| Service power supply |
24 V DC, 400 mA (FX1N); 250/460 mA (FX2N/FX2NC)
ripple ratio at maximum load:=±5% |
| Protection |
IP 20 |
| Noise durability |
1000 Vpp with noise generator; 1 ms at 30 – 100
Hz |
| Dielectric withstand voltage |
1,500 V AC, 1min. |
| Ambient relative humidity |
35 – 85%(non-condensing) |
| Shock resistance |
FX1N: 15 G (3 times in 3 directions) for 11 ms;
FX2N: 10 G (3 times in 3 directions) |
| Vibration resistance |
FX1N: 1 G (resistance to vibrations from 57–150
Hz for 80 minutes along all 3 axes); 0.5 G for
DIN railmounting
FX2N/FX2NC: 2 G (resistance to vibrations from
10 – 55 Hz for 2 hours along all 3 axes;
0.5 G for DIN railmounting |
| Insulation resistance |
500V DC, 5MOhm |
| Ground |
Class 3 |
| Fuse |
Up to FX1N-24: 1 A; from FX1N-40: 3 A; from
FX2N-32: 3.15 A; fromFX2N-48: 5 A; FX2NC-16MR-T-DS:
2.5 A; FX2NC-MT-DSS: 3.15 A |
| Environment |
Avoid environments containing corrosive gases,
install in a dust-free location. |
| Certifications |
UL/CSA/CE/LR/DNV , RINA/BV/GL/ECE |
| System
specifications: |
| Program
data: |
| I/O points (addresses) |
128 (+4 optional) |
| Address range |
Max. 84 inputs X0–X123, max. 64 outputs
Y0–Y77 |
| Program memory |
8,000 steps EEPROM (internal),
exchangeble EEPROM for easy program exchange |
| Cycle period |
0.55 – 1.0 µs /logical instruction |
| Programming language |
Step ladder, instruction list, SFC |
| Program execution |
Cyclical execution, refresh mode processing |
| Program protection |
Password protection with 3 protection levels |
| Number of instructions |
29 sequence instructions, 2 step ladder instructions,
89 applied instructions |
| Operands: |
| Internal relays |
1536 |
| Special relays |
256 (M8000-M8255) |
| Step ladder |
1000 |
| Timer |
256 ( 1,10,100 ms)
|
| Ext. preset value via potentiometer |
2 |
| Counter |
235 ; C0-C199 (16 bit), C200-C219
(32 bit) |
| High-speed counter |
6 single phase inputs (max. 60 kHz), 2 double
phase inputs (max. 30 kHz) |
| Real-time clock |
Year, month, day, hour, minut, second, weekday |
| Data register |
8000 (D0-D7999) |
| File register |
Max. 7,000 (parameter editable), Total registers=
8,000 |
| Index register |
16 |
| Special register |
256 (16 bit) (D8000-D8255) |
| Pointer |
128 (P0-P127) |
| Nestings |
8 (N0-N7) |
| Interrupt inputs |
6 |
| Constants |
16 bit: K: -32,768...+32,767;
hex: 0...FFFF |
| 32 bit: K: -2,147,483,648...+2,147,483,647;
hex: 0...FFFF FFFF |
|
|
|
| |
|
Base
Units |
Specifications: |
FX-1N 14MR-DS |
FX-1N 14MR-ES-UL |
FX-1N 14MT-DSS |
FX-1N 14MT-ESS-UL |
FX-1N 24MR-DS |
FX-1N 24MR-ES-UL |
FX-1N 24MT-DSS |
FX-1N 24MT-ESS-UL |
| Electrical
data: |
| Integrated inputs/outputs |
14 |
14 |
14 |
14 |
24 |
24 |
24 |
24 |
| Power
supply |
AC range (+10%, -15%) |
- |
100-240 V AC |
- |
100-240 V AC |
- |
100-240 V AC |
- |
100-240 V AC |
| Frequency at
AC [Hz] |
- |
50-60 (±
10%) |
- |
50-60 (±
10%) |
- |
50-60 (±
10%) |
- |
50-60 (±
10%) |
| DC range (+20%, -15%) |
12-24V DC |
- |
12-24V DC |
- |
12-24V DC |
- |
12-24V DC |
- |
| Max.
input apparent power [W] |
13 |
29 |
13 |
29 |
15 |
30 |
15 |
30 |
Inrush
current at ON
[A] |
100V AC |
- |
15A/5ms |
- |
15A/5ms |
- |
15A/5ms |
- |
15A/5ms |
| 200V AC |
- |
25A/5ms |
- |
25A/5ms |
- |
25A/5ms |
- |
25A/5ms |
| 24V DC |
25A/1ms |
- |
25A/1ms |
- |
25A/1ms |
- |
25A/1ms |
- |
| 12V DC |
22A/0,3 ms |
|
22A/0,3 ms |
|
22A/0,3 ms |
|
22A/0,3 ms |
|
| Allowable
momentary power failure time [ms] |
5 |
10 |
5 |
10 |
5 |
10 |
5 |
10 |
| External
service powersupply(24VDC) [mA] |
- |
400 |
- |
400 |
- |
400 |
- |
400 |
| Inputs: |
| Integrated inputs |
8 |
8 |
8 |
8 |
14 |
14 |
14 |
14 |
| Min.
current for logical 1 [mA] X0...X7
/ X10...X** |
4,5 / 3,5 |
4,5 / 3,5 |
4,5 / 3,5 |
4,5 / 3,5 |
4,5 / 3,5 |
4,5 / 3,5 |
4,5 / 3,5 |
4,5 / 3,5 |
| Max.
current for logical 0 [mA] |
1,5 |
1,5 |
1,5 |
1,5 |
1,5 |
1,5 |
1,5 |
1,5 |
| Response
time
[ms] |
For all base units of the MELSEC FX1N
series: 10 ms (at time of shipment), partly adjustable
between 0 and 15 ms |
| Outputs: |
| Integrated outputs |
6 |
6 |
6 |
6 |
10 |
10 |
10 |
10 |
| Output type |
Relay |
Relay |
Tranz. |
Tranz. |
Relay |
Relay |
Tranz. |
Tranz. |
| Max. switching voltage |
Generally for relay version:<264
V AC,<30 V DC; for transistor version: 5 – 30
V DC |
Max. output
current [A] |
- per output |
2 |
2 |
0,5 |
0,5 |
2 |
2 |
0,5 |
0,5 |
| - per group |
8 |
8 |
0,8 |
0,8 |
8 |
8 |
0,8 |
0,8 |
Max. switching
power [A] |
- inductive load |
80VA |
80VA |
12W |
12W |
80VA |
80VA |
12W |
12W |
- lamp load |
100W |
100W |
1,5W |
1,5W |
100W |
100W |
1,5W |
1,5W |
| Response
time
[ms] *=Y0,Y1-nél: < 5µs |
10 |
10 |
<0,2 * |
<0,2 * |
10 |
10 |
<0,2 * |
<0,2 * |
| Life of contacts (switching
times) |
3,000,000 (20VA-nél);
1,000,000 (35VA-nél); 200,000 (80VA-nél) |
| Mechanical
data: |
| Weight
[kg] |
0,45 |
0,45 |
0,45 |
0,45 |
0,45 |
0,45 |
0,45 |
0,45 |
| Dimensions
(WxHxD) [mm] |
90 x 90 x 75 |
90 x 90 x 75 |
90 x 90 x 75 |
90 x 90 x 75 |
90 x 90 x 75 |
90 x 90 x 75 |
90 x 90 x 75 |
90
x 90 x 75 |
|
|
|
|
|
|
|
|
|
|
|
| |
|
Base Units |
|
Specifications: |
FX-1N 40MR-DS |
FX-1N 40MR-ES-UL |
FX-1N 40MT-DSS |
FX-1N 40MT-ESS-UL |
FX-1N 60MR-DS |
FX-1N 60MR-ES-UL |
FX-1N 60MT-DSS |
FX-1N 60MT-ESS-UL |
| Electrical
data: |
| Integrated inputs/outputs |
40 |
40 |
40 |
40 |
60 |
60 |
60 |
60 |
| Power
supply |
AC range (+10%, -15%) |
- |
100-240 V AC |
- |
100-240 V AC |
- |
100-240 V AC |
- |
100-240 V AC |
| Frequency at AC [Hz] |
- |
50-60 (± 10%) |
- |
50-60 (± 10%) |
- |
50-60 (± 10%) |
- |
50-60 (± 10%) |
| DC range (+20%, -15%) |
24V DC |
- |
24V DC |
- |
24V DC |
- |
24V DC |
- |
| Max. input apparent
power.
[W] |
18 |
32 |
18 |
32 |
20 |
35 |
20 |
35 |
Inrush
current at ON
[A] |
100V AC |
- |
15A/5ms |
- |
15A/5ms |
- |
15A/5ms |
- |
15A/5ms |
| 200V AC |
- |
25A/5ms |
- |
25A/5ms |
- |
25A/5ms |
- |
25A/5ms |
| 24V DC |
25A/1ms |
- |
25A/1ms |
- |
25A/1ms |
- |
25A/1ms |
- |
| 12V DC |
22A/0,3 ms |
- |
22A/0,3 ms |
- |
22A/0,3 ms |
- |
22A/0,3 ms |
- |
| Allowable momentary
power failure time [ms] |
5 |
10 |
5 |
10 |
5 |
10 |
5 |
10 |
| Externalservicepowersupply(24VDC) [mA] |
- |
400 |
- |
400 |
- |
400 |
- |
400 |
| Inputs: |
| Integrated inputs |
24 |
24 |
24 |
24 |
36 |
36 |
36 |
36 |
| Min. current for logical
1 [mA] X0...X7 / 10...X** |
4,5 / 3,5 |
4,5 / 3,5 |
4,5 / 3,5 |
4,5 / 3,5 |
4,5 / 3,5 |
4,5 / 3,5 |
4,5 / 3,5 |
4,5 / 3,5 |
| Max. current for logical
0 [mA] |
1,5 |
1,5 |
1,5 |
1,5 |
1,5 |
1,5 |
1,5 |
1,5 |
| Response time [ms] |
For all base units of the MELSEC FX1N series:
10 ms (at time of shipment), partly adjustable between
0 and 15 ms |
| Outputs: |
| Integrated outputs |
16 |
16 |
16 |
16 |
24 |
24 |
24 |
24 |
| Output type |
Relay |
Relay |
Tranz. |
Tranz. |
Relay |
Relay |
Tranz. |
Tranz. |
| Max. switching voltage |
Generally for relay version:<264 V AC,<30
V DC; for transistor version: 5 – 30 V DC |
Max. output
current |
- per output |
2 |
2 |
0,5 |
0,5 |
2 |
2 |
0,5 |
0,5 |
| - per group |
8 |
8 |
0,8 |
0,8 |
8 |
8 |
0,8 |
0,8 |
Max. switching
power |
- inductive load |
80VA |
80VA |
12W |
12W |
80VA |
80VA |
12W |
12W |
- lamp load |
100W |
100W |
1,5W |
1,5W |
100W |
100W |
1,5W |
1,5W |
| Response
time
[ms] *=Y0,Y1-nél: < 5µs |
10 |
10 |
<0,2 * |
<0,2 * |
10 |
10 |
<0,2 * |
<0,2 * |
| Life of contacts (switching times) |
3,000,000 (20VA-nél);
1,000,000 (35VA-nél); 200,000 (80VA-nél) |
| Mechanical
data: |
| Weight [kg] |
0,65 |
0,65 |
0,65 |
0,65 |
0,8 |
0,8 |
0,8 |
0,8 |
| Dimensions (Wx H x
D) [mm] |
130 x 90 x 75 |
130 x 90 x 75 |
130 x 90 x 75 |
130 x 90 x 75 |
175 x
90 x 75 |
175 x
90 x 75 |
175 x
90 x 75 |
175 x